Heathkit model IG-1271

Function Generator

 

Date Calibrated:   _____/_____/_____

 

         The Accuracy of the calibration of the IG-1271 Function Generator is dependent upon the accuracy of the Oscilloscope used.

 

There are two methods described here for calibrating the Function Generator.

 

o    Method #1 requires the use of a triggered oscilloscope and a frequency counter.

 

o    Method #2 requires the use of a triggered oscilloscope or an audio distortion analyzer.

 

* * * * * * *

Handle and Cover Removal

 

(    )         Disconnect all external cables, components, and wires from all the equipment input and output terminals.

 

(    )         Disconnect the Function Generator line cord from the AC power line.

 

(    )         Remove the two Thumb screws and hardware along with the handle from the sides of the cabinet.

 

(    )         Remove the four screws from the rear and bottom of the cabinet.

 

(     )        Slide the top cover off the chassis. 

 

  CAUTION:    Dangerous AC voltage is present around the line cord leads on the circuit board and on the back of                      switch (SW-3).

 

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

 

Calibration Procedure method #1

 

Ancillary Equipment Needed

 

Frequency Counter

Triggered Oscilloscope

Audio Distortion Analyzer

 

* * * * * * *

FRONT PANEL INITIAL ADJUSTMENTS

Refer to Figure 2-1 on page 39

 

(    )         Set the ATTENUATION (dB) switch (SW-3) [black knob] to the 10 position.

 

(    )         Set the FREQUENCY MULTIPLIER switch (SW-1) [black knob] to the 1k position.

 

(    )         Set the FUNCTION switch (SW-2) [red knob] to the sawtooth wave position.

 

CIRCUIT BOARD INITIAL ADJUSTMENTS

Refer to Figure 1-2

Fold-out page 33

 

(    )         Set the HIGH FREQ DIAL ADJ (R4) to the center of rotation.

 

(    )         Set the LOW FREQ DIAL ADJ (R2) control to the center of rotation.

 

(    )         Set the SYM ADJ control (R7) to the center of rotation.

 

BNC CABLE CONNECTIONS

Refer to Figure 1-1

Fold-out page 33

 

(    )         Connect a BNC tee-connector to the vertical input of the Oscilloscope.

 

(    )         Connect a BNC tee-connector to the input of the Frequency Counter.

 

(    )         Connect a BNC cable between the output of the Function Generator and the vertical input of the Oscilloscope.

 

(    )         Connect a BNC cable between the vertical input of the Oscilloscope and the input of the Frequency Counter.

 

(    )         Connection to the Audio Distortion Analyzer is not made at this time.

 

(    )         Connect the Function Generator, Oscilloscope, and the Frequency Counter line cords to the AC power line.

 

(    )         Adjust the VARIABLE control (R33 & SW5) [red knob] clockwise until control clicks to the ON position.

 

(    )         Set the Frequency Generator and the Oscilloscope to their ON positions and allow the instruments to warm up.

 

* * * * * * *

OSCILLOSCOPE INITIAL SETUP

 

(    )         Set the vertical input attenuator switch to the 5 V/DIV position.

 

(    )         Set the Trigger source switch to INT.

 

(    )         Set the Trigger type switch to AC.

 

(    )         Set the Trigger polarity switch to + (positive).

 

(    )         Set the Trigger mode switch to AUTO.

 

* * * * * * *

FUNCTION GENERATOR ADJUSTMENTS

Refer figure 2-1 on page 39

 

*(    )  (    )  (    )1        Set the oscilloscope TIME/CM switch to the 1 mSEC/DIV position.

 

*(    )  (    )  (    )2        Adjust the FREQUENCY (Hz) control (R301) [black knob] to 0.1.

 

*(    )  (    )  (    )         Adjust the VARIABLE control (R33) [red knob] clockwise for a 20 volts peak-to-peak trace on the oscilloscope (see figure 3 on page 33).

 

*(    )  (    )  (    )3        Adjust the oscilloscope sweep rate until one complete sawtooth trace is displayed (see figure 3 on page 33).

 

NOTE:    It may be necessary to adjust the LOW FREQ DIAL ADJ control (R2) [circuit board] to obtain this trace.

 

*(    )  (    )  (    )4        Adjust the LOW FREQ DIAL ADJ control (R2) [circuit board] until the negative going ramp covers five divisions (see figure 4 on page 33).

 

*(    )  (    )  (    )         Set the oscilloscope Trigger polarity switch to -- (negative).

 

*(    )  (    )  (    )5        Adjust the SYM ADJ control (R7) [circuit board] until the positive going ramp covers five divisions (see figure 5 on page 33).

 

*(    )  (    )  (    )6        Adjust the DC OFFSET ADJ control (R32) [circuit board] until the trace is equally positioned above and below the zero reference line on the Oscilloscope (see figure 5 on page 33).

 

*(    )  (    )  (    )         Set the oscilloscope TRIGGER polarity to + (positive).

 

*(    )  (    )  (    )7        Adjust the FREQUENCY (Hz) control (R301) [black knob] to 10.

 

*(    )  (    )  (    )8        Adjust the HIGH FREQ DIAL ADJ control  (R4) [circuit board] until the Frequency Counter reads 10 kHz.

 

*(    )  (    )  (    )9        Adjust the FREQUENCY (Hz) control (R301) [black knob] to 1.

 

*(    )  (    )  (    )10       Adjust the LOW FREQ DIAL ADJ control (R2) [circuit board] until the Frequency Counter reads 1000 Hz.

 

NOTE:    The adjustments of the LOW FREQ DIAL ADJ control (R2) and the SYM ADJ control (R7) [circuit board] interact and have a direct relation to the amount of distortion output by the Function Generator.

 

(    )11       Repeat the above thirteen marked (*) steps twice more.

 

(    )12       Adjust the FREQUENCY (Hz) control (R301) [black knob] to 10.

 

(    )13       Set the FREQUENCY MULTIPLIER switch (SW1) [black knob] to the 10k position.

 

(    )14       Adjust the 10k ADJ trimmer (C4) [circuit board] until the Frequency Counter reads 100 kHz.

 

(    )15       Set the FREQUENCY MULTIPLIER switch (SW1) [black knob] to the 100k position.

 

(    )16       Adjust the 100k ADJ trimmer (C3) [circuit board] until the Frequency Counter reads 1 MHz.

 

(    )         Disconnect all external cables from the output terminals.

 

(    )         Calibration procedure [method #1] is complete.

 

(    )         Proceed to the Distortion Adjustments section below.

 

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

 

Calibration Procedure method #2

 

Ancillary Equipment Needed

 

Audio distortion analyzer

Triggered Oscilloscope

 

* * * * * * *

FRONT PANEL INITIAL ADJUSTMENTS

Refer to Figure 2-1 on page 39

 

(    )         Set the ATTENUATION (dB) switch (SW-3) [black knob] to the 10 position.

 

(    )         Set the FREQUENCY MULTIPLIER switch (SW-1) [black knob] to the 1k position.

 

(    )         Set the FUNCTION switch (SW-2) [red knob] to the sawtooth wave position.

 

CIRCUIT BOARD INITIAL ADJUSTMENTS

Refer to Figure 1-2

Fold-out page 33

 

(    )         Set the HIGH FREQ DIAL ADJ control (R4) to the center of rotation.

 

(    )         Set the LOW FREQ DIAL ADJ control (R2) to the center of rotation.

 

(    )         Set the SYM ADJ control (R7) to the center of rotation.

 

BNC CABLE CONNECTIONS

Refer to Figure 1-3 on page 34

 

(    )         Connect a BNC cable between the output of the Function Generator and the vertical input of the Oscilloscope.

 

(    )         Connect the Function Generator, Oscilloscope, and Audio Distortion Analyzer line cords to the AC power line.

 

(    )         Adjust the VARIABLE control (R33 & SW5) [red knob] clockwise until control clicks to the ON position.

 

(    )         Set the Oscilloscope and the Audio Distortion Analyzer to their ON positions and allow the instruments to warm up.

 

* * * * * * *

OSCILLOSCOPE INITIAL SETUP

 

(    )         Set the vertical input attenuator switch to the 5 V/DIV position.

 

(    )         Set the Trigger source switch to INT.

 

(    )         Set the Trigger type switch to AC.

 

(    )         Set the Trigger polarity switch to + (positive).

 

(    )         Set the Trigger mode switch to AUTO.

 

* * * * * * *

FUNCTION GENERATOR ADJUSTMENTS

Refer figure 2-1 on page 39

 

*(    )  (    )  (    )1        Set the oscilloscope TIME/CM switch to the 1 mSEC/DIV position.

 

*(    )  (    )  (    )2        Adjust the FREQUENCY (Hz) control (R301) [black knob] to 0.1.

 

*(    )  (    )  (    )         Adjust the VARIABLE control (R33) [red knob] clockwise for a 20 volts peak-to-peak trace on the oscilloscope (see figure 3 on page 35).

 

*(    )  (    )  (    )3        Adjust the oscilloscope sweep rate until one complete sawtooth trace is displayed (see figure 3 on page 35).

 

NOTE:    It may be necessary to adjust the LOW FREQ DIAL ADJ control (R2) [circuit board] to obtain this trace.

 

*(    )  (    )  (    )4        Adjust the LOW FREQ DIAL ADJ control (R2) [circuit board] until the negative going ramp covers five divisions (see figure 4 on page 35).

 

*(    )  (    )  (    )         Set the oscilloscope Trigger polarity switch to -- (negative).

 

*(    )  (    )  (    )5        Adjust the SYM ADJ control (R7) [circuit board] until the positive going ramp covers five divisions (see figure 5 on page 35).

 

*(    )  (    )  (    )         Set the oscilloscope Trigger polarity switch to + (positive).

 

*(    )  (    )  (    )6        Adjust the FREQUENCY (Hz) control (R301) [black knob] to the 10 indication.

 

*(    )  (    )  (    )7        Set the oscilloscope TIME/CM switch to the 10 mSEC/DIV position.

 

*(    )  (    )  (    )8        Adjust the HIGH FREQ DIAL ADJ control  (R4) [circuit board] until the positive going ramp plus the negative going ramp covers ten oscilloscope divisions.

 

(    )9        Repeat the above eleven marked (*) steps twice more.

 

(    )10       Adjust the FREQUENCY (Hz) control (R301) [black knob] to 10.

 

(    )11       Set the FREQUENCY MULTIPLIER switch (SW-1) [black knob] to the 10k position.

 

(    )12       Set the oscilloscope TIME/CM switch to the 2 mSEC/DIV position.

 

(    )13       Adjust the 10k ADJ trimmer (C4) [circuit board] until the positive going ramp plus the negative going ramp covers five oscilloscope divisions (see figure 13 on page 35).

 

(    )14       Set the FREQUENCY MULTIPLIER switch (SW1) [black knob] to the 100k position.

 

(    )15       Set the oscilloscope TIME/CM switch to the .5 mSEC/DIV position.

 

(    )16       Adjust the 100k ADJ trimmer (C4) [circuit board] until five cycles are displayed spanning ten divisions on the oscilloscope (see figure 16 on page 35).

 

(    )         Calibration procedure [method #2] is complete.

 

(    )         Proceed to the Distortion Adjustments section below.

 

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

 

Distortion Adjustments

 

Ancillary Equipment Needed

 

Audio Distortion analyzer

Triggered Oscilloscope

Notch Filter (see page 32)

 

There are two methods described here for adjusting for distortion:

 

o    Method #1 requires the use of a Triggered oscilloscope.

 

o    Method #2 requires the use of an audio distortion analyzer.

 

* * * * * * *

FRONT PANEL INITIAL ADJUSTMENTS

Refer to Figure 2-1 on page 39

 

(    )         Adjust the FREQUENCY (Hz) control (R301) [black knob] to the full counter clockwise position.

 

(    )         Set the FREQUENCY MULTIPLIER switch (SW-1) [black knob] to the 1k position.

 

(    )         Set the FUNCTION switch (SW-2) [red knob] to the sawtooth wave position.

 

(    )         Set the ATTENUATION (dB) switch (SW-3) [black knob] to the 0 position.

 

(    )         Adjust the VARIABLE control (R33) [red knob] to the full clockwise position.

 

(    )         Set the function generator and the oscilloscope or the audio distortion analyzer to their ON positions and allowed to warm up.

 

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

 

Distortion Compensation method #1

 

Ancillary Equipment Needed

 

Triggered Oscilloscope

Notch Filter (see page 32)

 

* * * * * * *

OSCILLOSCOPE INITIAL SETUP

 

(    )         Set the TIME/CM switch to the 1 mSEC/DIV position.

 

(    )         Set the vertical input attenuator switch to the 5 V/DIV position.

 

(    )         Set the Trigger source switch to INT.

 

(    )         Set the Trigger type switch to AC.

 

(    )         Set the Trigger polarity switch to + (positive).

 

(    )         Set the Trigger mode switch to AUTO.

 

(    )         Connect the output of the Function Generator to the vertical input of the Oscilloscope (figure 1-3 on page 34).

 

(    )         Adjust the VARIABLE control (R33) [red knob] clockwise for a 20 volts peak-to-peak trace on the oscilloscope.

 

(    )         Disconnect the vertical input of the Oscilloscope.

 

* * * * * * *

NOTCH FILTER CONNECTIONS

Refer to figure 1-4

Fold out page 34

 

(    )         Connect the output of the Function Generator to the input of the Notch Filter [loop end].

 

(    )         Connect the Oscilloscope’s vertical input to the Notch Filter’s output [straight end].

 

* * * * * * *

CIRCUIT BOARD ADJUSTMENTS

Refer to Figure 1-2

Fold out page 33

 

*(    )  (    )  (    )         Adjust the FREQUENCY (Hz) control (R301) [black knob] until a minimum output indication is obtained.

 

*(    )  (    )  (    )         Adjust the + DIST control (R23) [circuit board] until a minimum output indication is obtained.

 

*(    )  (    )  (    )         Adjust the -- DIST control (R26) [circuit board] until a minimum output indication is obtained.

 

(    )         Repeat the above three marked (*) steps twice more.

 

(    )         Distortion compensation [method #1] is complete.

 

(    )         Disconnect all external cables from all terminals.

 

(    )         Set the VARIABLE control (R33 & SW5) [red knob] counter-clockwise to the OFF position.

 

(    )         All calibrations and adjustments are now completed.

 

(    )         Disconnect the line cord from the AC power lines.

 

(    )         Re-install cover and handle.

 

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

 

Distortion Compensation method #2

 

Ancillary Equipment Needed

 

Audio Distortion Analyzer

Notch Filter (see page 32)

 

 

* * * * * * *

AUDIO DISTORTION ANALYZER INITIAL SETUP

 

(    )         Set the Audio Distortion Analyzer attenuator switch to the 20 volts scale*.

 

(    )         Connect the output of the Function Generator to the input of the Audio Distortion Analyzer (figure 1-3 on page 34).

 

(    )         Adjust the VARIABLE control (R33) [red knob] clockwise for a 20 volts* meter indication.

 

NOTE:    * Use which ever Audio Distortion Analyzer attenuation setting that produces a full scale indication at the maximum generator output.

 

(    )         Disconnect the input to the Audio Distortion Analyzer.

 

* * * * * * *

NOTCH FILTER CONNECTIONS

Refer to figure 1-4

Fold out page 34

 

 (    )        Connect the output of the Function Generator to the input of the Notch Filter [loop end].

 

(    )         Connect the Audio Distortion Analyzer’s input to the Notch Filter’s output [straight end].

 

* * * * * * *

CIRCUIT BOARD ADJUSTMENTS

Refer to Figure 1-2

Fold out page 33

 

*(    )  (    )  (    )         Adjust the FREQUENCY (Hz) control (R301) [black knob] until a minimum output indication is obtained.

 

NOTE:    Use which ever attenuation setting that produces a full scale indication at this minimum generator output.

 

*(    )  (    )  (    )         Adjust the + DIST control (R23) [circuit board] until a minimum output indication is obtained.

 

*(    )  (    )  (    )         Adjust the -- DIST control (R26) [circuit board] until a minimum output indication is obtained.

 

(    )         Repeat the above three marked (*) steps twice more.

 

(    )         Distortion compensation [method #2] is complete.

 

(    )         Disconnect all external cables from all terminals.

 

(    )         Set the VARIABLE control (R33 & SW5) [red knob] counter-clockwise to the OFF position.

 

(    )         All calibrations and adjustments are now completed.

 

(    )         Disconnect the line cord from the AC power lines.

 

(    )         Re-install cover and handle.